Description
Last updated: November 11, 2026.
This is the VR fire extinguisher training module in Humulo’s OSHA library. A trainee puts on a standalone headset, walks a shipyard, and is scored on classifying the fire, pulling the alarm, selecting an extinguisher that matches the class, pulling the pin, and discharging it with a correct aim and sweep from a safe standoff. One run is about 15 minutes and can be repeated as many times as you want. It comes with every Humulo headset at no per-module cost. It replaces the live-burn logistics — the pan, the fuel, the recharges, the outdoor space, the weather-dependent schedule — not the fire itself.
Module specifications
| Spec | Detail |
|---|---|
| Format | Standalone VR, single trainee per headset |
| Runtime | 15+ minutes per run, repeatable without limit |
| Environment | Shipyard worksite with Class A, B and C ignition sources |
| Fire classes in the scenario | Class A, Class B, Class C. Not Class D, not Class K (see the class table below) |
| Scored actions | Hazard classification, alarm, extinguisher selection, pin pull, aim point, sweep, standoff distance |
| Instructor-adjustable settings | None. The scenario, the hazard mix and the pass criteria are fixed for every trainee |
| Record produced | Per-trainee completion record; an incorrect class or an unsafe standoff produces a failed attempt rather than a pass |
| Hardware | PICO 4 Ultra Enterprise (Meta Quest on request) |
| Network | Runs offline once loaded; suitable for air-gapped and secured sites |
| Group delivery | Multicast kit mirrors a headset to a TV or projector for a classroom |
| OSHA standard | 29 CFR 1910.157(g) |
| Licensing | 12-month license per trainee, included with the headset |
Which fire class takes which extinguisher, and which classes this module covers
The decision that gets people hurt is not the sweep, it is the selection. Water on an energized panel or on burning magnesium makes the fire worse. This is the reference table for the five classes, what puts each one out, where 29 CFR 1910.157 addresses it, and whether this module trains it.
| Class | What is burning | Agents that work | Where 1910.157 addresses it | In this module? |
|---|---|---|---|---|
| Class A | Ordinary combustibles: wood, paper, cloth, rubber, most plastics | Water, foam, ABC dry chemical | (d)(2) sets a 75 ft maximum travel distance to an extinguisher; (d)(3) lets uniformly spaced standpipe or hose systems stand in for Class A extinguishers under stated conditions | Yes |
| Class B | Flammable liquids and gases: fuels, solvents, oils, paint | ABC or BC dry chemical, carbon dioxide, AFFF foam | (d)(4) sets a 50 ft maximum travel distance from the hazard area | Yes |
| Class C | Energized electrical equipment: panels, motors, wiring | Non-conductive agents only: carbon dioxide, dry chemical, clean agent. De-energize and the fire reverts to A or B | (d)(5) says distribution follows the pattern already used for the Class A or Class B hazards present | Yes |
| Class D | Combustible metals: magnesium, titanium, sodium, potassium, lithium | Dry powder agents such as sodium chloride, copper or graphite. Never water | (d)(6) sets a 75 ft maximum travel distance to the agent and requires it wherever combustible metal powders, flakes or shavings are generated at least once every two weeks | No |
| Class K | Cooking oils and fats in commercial kitchens | Wet chemical (potassium acetate or citrate), which saponifies the oil surface | Nowhere. Class K does not appear in 1910.157. It is an NFPA 10 class | No |
That last row is worth pausing on, because several VR fire extinguisher products are advertised as covering “classes A, B, C, D and K” under 29 CFR 1910.157(g). Classes A through D are the ones 1910.157(d) is built around. Class K is not in the standard. A module that teaches it is teaching something useful for a kitchen, but it is not covering an extra OSHA class, because there is no extra OSHA class to cover.
If the hazard you actually have to train is combustible metal or a commercial kitchen line, this module is the wrong module and we would rather say so now. Those are scenario builds, not settings — see custom VR training development.
PASS, and what the module scores at each step
Every extinguisher course teaches PASS. The difference between a poster and a simulation is whether anything happens when the trainee gets a step wrong. Here is the sequence this module runs and what it checks.
| Step | What the trainee does | What the module checks |
|---|---|---|
| Before PASS: classify | Walks the shipyard and tags combustibles, flammable liquids and energized equipment as Class A, B or C | Classification is scored per hazard. This is the judgement 1910.157(g)(1) calls the hazards of incipient-stage firefighting |
| Before PASS: alarm | Pulls the fire alarm before engaging the fire | Required. Engaging first is a procedural failure, not a style preference |
| Before PASS: select | Locates an extinguisher, checks it, carries it to the fire | Wrong class for the fire fails the attempt |
| P — Pull | Pulls the pin | Modelled as a discrete action. A discharge attempt with the pin still in does nothing, which is the same thing that happens in a real hallway |
| A — Aim | Aims at the base of the fire | Aim point is checked. Aiming at the flame tops does not extinguish anything |
| S — Squeeze | Squeezes the handle | Continuous discharge is required to put the fire out |
| S — Sweep | Sweeps side to side across the base | Sweep motion is checked, and so is standoff distance. Standing too close fails the attempt |
Where this module sits among the other kinds of extinguisher trainer
There are four things a safety manager can buy, and they do not train the same skills. We sell one of them.
| Type | Examples | Space and consumables | Trains well | Cannot do |
|---|---|---|---|---|
| Gas-fired live pan | Dräger TUTOR and similar propane pan trainers | Dedicated outdoor or ventilated space, propane, extinguisher recharges after every discharge | Real heat, real weight, real discharge recoil. Nothing else reproduces that | Throughput and schedule. One pan gets through a few dozen people a day, in acceptable weather, and most employees get a single discharge a year |
| Laser or LED projected flame | Lion BullsEye | A clear room, no fuel, no recharges; hardware cost per unit | Aim and sweep detection in a real physical space, with instructor-saved scenarios | The walk-up decisions. There is no hazard to classify and usually no wrong extinguisher to pick up |
| Standalone VR headset | Humulo, Lion QuickFire XR, Xtintor VR, Toolkit Technologies, Fyware, QuakeLogic | No dedicated space, no fuel, no recharges | The whole decision chain: classify, alarm, select, pull, aim, squeeze, sweep, standoff — repeatable per trainee at no marginal cost | Heat, weight, recoil |
| Fixed-screen sensor unit | Older display-and-orientation-sensor trainers | A desk | The PASS motion in outline | Spatial judgement and standoff distance. Several of these units never modelled the pin or the trigger at all |
Humulo recommendation: if your authority having jurisdiction, your insurer or your fire marshal wants a live-fire evolution, buy or rent the pan and do not let anyone sell you out of it. What VR replaces at a real saving is the annual refresher for the large population of employees who will never touch a live extinguisher in training, because the pan only gets through thirty people a day.
How this maps to OSHA 1910.157(g), paragraph by paragraph
| Paragraph | What it requires | What this module does about it |
|---|---|---|
| 1910.157(g)(1) | Where the employer has provided portable extinguishers for employee use, an educational program covering the general principles of extinguisher use and the hazards of incipient-stage firefighting | Carries that content as a scored scenario rather than a lecture: general principles in the PASS sequence, incipient-stage judgement in the classify-and-alarm steps |
| 1910.157(g)(2) | That education, at initial employment and at least annually after | Produces a dated per-trainee completion record you can run again next year at no additional license cost |
| 1910.157(g)(3) | Training on the appropriate equipment for employees designated to use firefighting equipment as part of an emergency action plan | Covers extinguisher selection and use. It does not cover hose lines, SCBA or anything else a designated response team may be issued |
| 1910.157(g)(4) | That (g)(3) training, on initial assignment to the designated group and at least annually after | Same annual record, same fixed pass criteria, so year-over-year records are comparable |
The honest limit: OSHA does not approve, certify or endorse training products from any vendor, and Humulo does not claim it does. A module can deliver and document the required content. Whether your program as a whole satisfies 1910.157(g) is a question about your program, not about our software.
What NFPA 10 does and does not require of you
“NFPA 10 compliant” shows up in a lot of extinguisher training marketing, including from VR vendors, so it is worth being precise. NFPA 10, the Standard for Portable Fire Extinguishers, is not incorporated by reference into the OSHA general industry standards. 29 CFR 1910.6 lists the NFPA documents that are, and NFPA 10 is not among them; 1910.157 does not cite it either. Your federal training obligation for portable extinguishers is 1910.157(g), full stop.
NFPA 10 can still reach you, through your state fire code, your insurer or your authority having jurisdiction, and where it does it is a real obligation. It is just not a federal OSHA one, and no training product can make you compliant with it. Humulo does not claim NFPA 10 compliance for this module.
What is fixed, and what you can actually change
Some VR extinguisher products give the instructor sliders for difficulty, fire intensity and extinguisher availability. This one does not, and that is a decision rather than a gap.
A completion record is only worth something if the bar was identical for everyone who holds one. 1910.157(g)(2) and (g)(4) make extinguisher training an annually recurring record, so you are not producing one document, you are producing a series that an inspector, an insurer or a plaintiff’s expert can line up side by side. A run that was quietly turned down for a trainee who was struggling produces a record you cannot defend three years later. So the scenario, the hazard mix, the class distribution and the pass criteria are the same for a new hire and for a plant manager.
What you can change: how many times a trainee repeats the run, which is unlimited and costs nothing; whether the class watches on a TV through the $500 multicast kit before rotating through the headset; and the scenario itself, which is a custom development conversation, not a setting.
Licensing and price
This module is not priced on its own. It comes with every Humulo headset along with the whole library, and every trainee gets their own seat at no extra cost. Most VR training vendors will not publish a number without a sales call. Humulo’s are on the site, and they are the same numbers quoted to a two-person shop and to a Fortune 100 plant.
| Line item | Published price |
|---|---|
| Trainee seats (full library, this module included) | Unlimited, included with every headset |
| Headset, year 1 | $2,349 |
| Annual headset service, year 2 onward | $750 per headset |
| Account activation, one time | $1,150 |
| Multicast kit (mirror one headset to a TV or projector) | $500 |
| 30-day pilot, 1 headset | $3,499, fully refundable within 30 days |
No multi-year contract. Year-two renewal is optional. Full detail is on the VR training pricing page, and the per-employee math against classroom and e-learning delivery is broken out in safety training cost per employee.
Frequently asked questions
Does VR fire extinguisher training satisfy OSHA?
OSHA does not approve or certify training products from any vendor. 29 CFR 1910.157(g) requires an educational program at hire and annually, plus equipment training for employees designated to fight fires under an emergency action plan. A VR module can deliver and document that content. If a fire marshal, insurer or authority having jurisdiction separately requires a live-fire evolution, VR does not replace it.
Which fire classes does this module cover?
Class A, Class B and Class C, which are present as combustibles, flammable liquids and energized electrical equipment in the shipyard scenario. It does not cover Class D combustible metals or Class K cooking media. For context, 1910.157(d)(6) is the Class D provision in the standard, and Class K does not appear in 1910.157 at all — it is an NFPA 10 class.
Is this module NFPA 10 compliant?
No training product can make you compliant with NFPA 10, and Humulo does not claim it. NFPA 10 is not incorporated by reference into the OSHA general industry standards at 29 CFR 1910.6, and 1910.157 does not cite it. Your federal obligation for portable extinguisher training is 1910.157(g). NFPA 10 may still apply to you through state fire code, your insurer or your authority having jurisdiction.
Does it teach the PASS method?
Yes, and it scores each step rather than describing it. The pin pull is a discrete action, so a discharge with the pin still in does nothing. The aim point is checked against the base of the fire. The sweep motion is checked, and so is standoff distance — standing too close fails the attempt. Classification, the alarm and extinguisher selection are scored before PASS begins.
Can an instructor adjust the difficulty or the fire intensity?
No, by design. The scenario, hazard mix and pass criteria are identical for every trainee so that a year of completion records is internally comparable. 1910.157(g)(2) and (g)(4) make this an annual record, and adjustable difficulty makes a series of annual records impossible to defend. What is unlimited is repetition: a trainee can run it until they pass, at no additional cost.
How does this compare to a live-burn pan or a laser extinguisher trainer?
A gas-fired pan is the only one of the three that delivers real heat, weight and recoil, and it is the right purchase if your authority having jurisdiction wants a live-fire evolution. A laser or LED trainer such as Lion BullsEye checks aim and sweep in a real room but gives the trainee no hazard to classify and usually no wrong extinguisher to pick up. VR covers the full decision chain, including classification and selection, with no space, fuel or recharge cost and unlimited repeats, and it is the only one of the three that costs nothing extra per additional trainee.
How often does extinguisher training have to be repeated?
Annually, under two separate paragraphs. 1910.157(g)(2) requires the general educational program at initial employment and at least annually after. 1910.157(g)(4) requires the equipment training for designated emergency-response employees on initial assignment and at least annually after. Repeat runs of this module carry no additional license cost.
How long does the module take?
About 15 minutes per run. Trainees can repeat it as many times as they want, which is the practical difference from a burn pan where each employee typically gets one discharge.
What does VR fire extinguisher training cost?
Pricing is per headset, not per trainee: every trainee gets their own seat with the full Humulo library, not just this module, at no extra cost. Headsets are $2,349 in year one and $750 per headset for service after that. A one-headset 30-day pilot is $3,499 and is fully refundable.
Which headsets does it run on?
PICO 4 Ultra Enterprise, with Meta Quest available on request. It runs offline once loaded, so it works on secured or air-gapped sites where a cloud-dependent platform will not.
Can we train a group with one headset?
Yes. The $500 multicast kit mirrors the headset view to a TV or projector so a class watches the run and the instructor debriefs it, then trainees rotate through.
How to verify what is on this page
| Claim | Where to check it | Checked |
|---|---|---|
| 1910.157(g)(1)–(g)(4) training and annual-recurrence requirements | osha.gov, 29 CFR 1910.157, paragraph (g) | 2026-11-11 |
| Class A/B/C/D travel distances and the two-week combustible-metal trigger | osha.gov, 29 CFR 1910.157(d)(2)–(d)(6) | 2026-11-11 |
| Class K does not appear in 1910.157 | osha.gov, full text of 29 CFR 1910.157 | 2026-11-11 |
| NFPA 10 is not incorporated by reference by OSHA general industry | osha.gov, 29 CFR 1910.6, the full list of incorporated NFPA documents | 2026-11-10 |
| Prices in the table above | humulo.com/vr-training-pricing/ and the product pages on this site | 2026-11-11 |
| Competitor trainer types and features named in the comparison table | Each vendor’s own product page | 2026-11-11 |
| Module runtime, scored actions and hardware | This page and the downloadable spec sheet below; verifiable in a 30-day refundable pilot | 2026-11-11 |
Everything on this page is written by the vendor that sells the product, which is true of every page you will find on this query. The table above is here so that the parts that are not our opinion can be checked against a primary source rather than taken on trust.
Course detail
12-month expiration subscription, purchased per unique user. Average experience length 15+ minutes.
Learning objectives
- Identify major hazards
- Describe types of hazards
- Protect themselves from these hazards
- Recognize employer requirements to protect workers from these hazards
Enabling objectives
- Identify Class A fire hazards
- Identify Class B fire hazards
- Identify Class C fire hazards
- Alert emergency services by pulling the fire alarm
- Find the fire extinguisher and prepare it for use
- Fight the fire with appropriate spraying technique
- Put the fire out
Student materials
- PICO 4 Ultra Enterprise virtual reality headset (Meta Quest on request)
- Humulo’s VR fire suppression software
Scenario overview
Trainees begin by touring a shipyard worksite and identifying fire hazards: Class A combustibles, Class B flammable liquids, Class C electrical hazards, and general construction-site fire hazards. After a fire breaks out, the trainee pulls the fire alarm to alert emergency personnel, then picks up a fire extinguisher, pulls the pin and fights the fire. The extinguisher has to be sprayed side to side at the base of the fire, continuously, until the fire is out. The trainee has to hold a safe standoff distance and use correct technique for the attempt to count.
Related
Full product and deployment detail is on the VR fire extinguisher training page, and the vendor-by-vendor comparison is in VR fire extinguisher training options compared. Other modules in the library: VR forklift training, VR lockout/tagout training, VR confined space training. Program-level overview: enterprise VR safety training. Also in the library: slips, trips and falls, fall safety climbing simulator, hand safety, HAZWOPER/HazCom. Every standard is indexed on OSHA training requirements.
Download the spec sheet (PDF)
The one-page VR fire extinguisher training spec sheet (PDF) carries the full specification table, how the module maps to 29 CFR 1910.157, what a trainee actually does, and a plain statement of where the module stops — the parts a safety manager has to show a committee or attach to a purchase request. Download the VR fire extinguisher training spec sheet (PDF).
Spec sheets for the rest of the OSHA library: VR forklift training, VR lockout tagout training, VR confined space training.